AD SPACE AVAILABLE · BRAND PARTNERS WELCOME

Engineering Custom Column Prompts in Elicit for Standardized Numerical Outcomes and Effect Sizes

松下祥子 · 365Finds Editorial
Indexed 88,650 Wiki articles

Put 365 Wiki to work with your AI

Copy the prompt below, paste it into the AI you already use, then ask your question.

Download full Skill

Try it with the prompt first. If you use 365 Wiki often, install the full 365Wiki Skill so you do not have to paste it again. No regular AI? Gemini or Microsoft Copilot on the web will work.

365Wiki Skill

Systematic reviews and meta-analyses live and die by numerical precision. Yet anyone who has extracted data across fifty randomized controlled trials (RCTs) knows the reality: clinical trial reporting is chaotic. Sample sizes fluctuate between baseline enrollment, randomized allocation, and final analyzed cohorts. Continuous endpoints are reported haphazardly as mean ± standard deviation, mean with standard error, medians with interquartile ranges, or percentage changes from baseline. Binary effect sizes (Risk Ratios, Odds Ratios, Hazard Ratios) sit buried in dense outcome tables, figure legends, or supplementary appendices.

Generic AI chat tools fail miserably at this task. When asked to "extract study outcomes," standard large language models conflate baseline randomized patients with final per-protocol completers, drop measurement units, hallucinate missing standard deviations, and generate unstructured narrative paragraphs. Researchers are then forced to spend hours manually cleaning text strings before data can be imported into Cochrane Review Manager (RevMan) or R packages (meta, metafor).

Elicit solves this bottleneck through native Custom Extraction Columns. Rather than treating paper extraction as an open-ended conversation, Elicit executes extraction as structured data labeling against full-text PDFs. When reviewers engineer rigorous, multi-tiered prompt instructions, Elicit delivers clean, standardized numbers and categorical variables paired with sentence-level source citations.

At 365Finds, our research benchmark is clear: Never extract clinical endpoints using monolithic, multi-variable prompts. To build an audit-ready, automated meta-analysis pipeline, systematic reviewers must configure atomic custom columns—isolating each numerical variable, enforcing strict output syntax, and establishing deterministic rules for edge cases and missing data.


The Anatomy of an Elicit Custom Column

In Elicit's Systematic Reviews workflow and Research Agent tables, adding a custom extraction column involves two distinct fields. Understanding how Elicit processes each field is essential for prompt engineering.

1. Column Name (The Semantic Anchor)

The column name should be a concise, natural language phrase describing the target variable (e.g., Analyzed Sample Size (Intervention) or Primary Outcome Mean ± SD (Post-Intervention)).

[!WARNING] Avoid database shorthand, code variables, or concatenated strings such as T01_N_int or OUTCOME_MEAN_SD_C. Elicit relies on natural language semantics to map the target concept to full-text PDF embeddings. Shorthand codes degrade retrieval quality and cause higher credit consumption.

2. Instructions / Description (The Extraction Protocol)

The instructions field is where prompt engineering takes place. Elicit's extraction engine treats this box as an operational standard operating procedure (SOP) given to a human research assistant. It supports multi-paragraph directives, strict negative constraints, formatting templates, and few-shot anchor examples.


The 4-Layer Column Prompt Engineering Framework

To eliminate AI ambiguity and extract numerical results that directly feed meta-analysis software, every custom column prompt should follow a four-layer structural template:

[Layer 1: Target Definition & Population Boundaries]
Define exactly what metric is sought and explicitly differentiate it from similar confounding variables (e.g., analyzed vs. enrolled).

[Layer 2: Strict Syntactic Formatting Template]
Specify the exact numerical syntax, mathematical symbols, decimal precision, and mandatory measurement units.

[Layer 3: Missingness & Fallback Token]
Instruct the model how to handle absent, incomplete, or ambiguous data using a fixed fallback token (e.g., "NR" for Not Reported).

[Layer 4: Few-Shot Anchor Examples]
Provide concrete examples of valid outputs and invalid outputs to calibrate the extraction engine.

Production-Ready Prompt Formulas for Meta-Analysis

Below are calibrated prompt templates engineered specifically for clinical trials and observational cohorts.

1. Sample Size: Distinguishing Analyzed Cohorts from Baseline Enrollment

A common failure mode in AI extraction is recording the baseline randomized count ($N_{\text{rand}}$) rather than the final analyzed cohort ($N_{\text{analyzed}}$), introducing severe attrition bias into meta-analytic weighting.

Column Name:

Analyzed Sample Size (Intervention Group)

Column Instructions:

Extract the total number of participants in the active intervention arm who were included in the final primary outcome analysis at the study endpoint.

Critical Rules:
1. Do NOT extract the initial baseline enrollment, screening, or randomized sample size if participants dropped out or were excluded prior to analysis.
2. If the study reports both Intention-to-Treat (ITT) and Per-Protocol (PP) populations, extract the ITT analyzed sample size.
3. Extract ONLY the integer value (digits only). Do not include descriptive words, labels, or variable names.
4. If the final analyzed sample size for this specific group cannot be determined from the text or tables, output strictly "NR".

Examples:
- Valid: 142
- Invalid: N = 142 patients
- Invalid: 150 enrolled, 142 analyzed

2. Continuous Outcomes: Mean ± Standard Deviation with Units

Meta-analysis software requires separate or cleanly delimited Mean and SD fields. Extracting mixed metrics (e.g., standard error or 95% CI reported as SD) invalidates pooled effect calculations.

Column Name:

Primary Outcome (Post-Intervention Mean ± SD)

Column Instructions:

Extract the post-intervention primary outcome numerical result for the intervention group at the primary follow-up endpoint.

Mandatory Formatting Requirements:
1. Format must strictly follow: [Mean] ± [SD] [Unit]
2. Use the "±" character to separate the Mean and Standard Deviation. Round numbers to one or two decimal places as presented in the paper.
3. Always include the measurement unit (e.g., mg/dL, mmHg, points).
4. Do NOT confuse Standard Error (SE) or 95% Confidence Interval (CI) with Standard Deviation (SD). If the authors only report Mean ± SE or Median (IQR), do NOT calculate or estimate SD. Output strictly "NR (SE reported)" or "NR (Median reported)".
5. If the outcome was not assessed or not reported, output "NR".

Examples:
- Valid: 24.5 ± 3.8 mg/dL
- Valid: -1.2 ± 0.4 mmHg
- Invalid: 24.5 (SD 3.8)
- Invalid: 24.5 ± 3.8
- Invalid: 24.5 (SE 0.8)

3. Binary Outcomes & Effect Sizes: Risk Ratios (RR) and 95% CIs

For dichotomous outcomes, extracting the relative effect size alongside its exact 95% confidence interval is critical for generic inverse-variance pooling in RevMan.

Column Name:

Primary Outcome Risk Ratio (RR and 95% CI)

Column Instructions:

Extract the adjusted or primary Risk Ratio (Relative Risk, RR) and its corresponding 95% Confidence Interval for the primary outcome comparison.

Syntax Rules:
1. Output format must strictly be: RR [95% CI Lower, Upper]
2. If only Odds Ratio (OR) or Hazard Ratio (HR) is reported, do NOT label it as RR. Output "NR (OR reported: <value>)" or "NR (HR reported: <value>)".
3. Extract the exact numbers reported. Do not round numbers beyond the author's reporting.
4. If no confidence interval is reported, provide the p-value: RR [p = <value>].
5. If the outcome is missing, output strictly "NR".

Examples:
- Valid: 0.78 [0.64, 0.95]
- Valid: 1.15 [0.98, 1.35]
- Invalid: RR = 0.78 (95% CI 0.64 to 0.95)
- Invalid: 0.78

4. Categorical Classifications: Analysis Population (ITT vs. PP)

Using multiple-choice constraints forces Elicit to categorize methodological approaches deterministically, preventing verbose free-text summaries.

Column Name:

Analysis Approach Type

Column Instructions:

Identify the statistical analysis framework used by the study authors for the primary outcome evaluation.

The answer must be strictly one of the following four options:
- Intention-to-Treat (ITT)
- Modified Intention-to-Treat (mITT)
- Per-Protocol (PP)
- Not Reported

Rules:
1. Select "Intention-to-Treat (ITT)" only if all randomized participants were analyzed in their assigned groups regardless of compliance or dropout.
2. Select "Modified Intention-to-Treat (mITT)" if authors excluded participants who did not receive at least one dose of intervention.
3. Select "Per-Protocol (PP)" if analysis was restricted only to participants completing full treatment protocol.
4. Output ONLY the exact category string. Do not append explanatory commentary.

Systematic Review Workflow: Verification and Quality Control

Engineering great prompts is only half the battle. Elicit's architecture is uniquely suited for systematic reviews because every cell contains an explicit provenance trail.

flowchart TD
    A["Upload PDFs or Search Literature\n(Ensure Full-Text Access)"] --> B["Configure Account Settings\n(Enable Premium PDF Parsing)"]
    B --> C["Design Atomic Custom Columns\n(4-Layer Prompt Framework)"]
    C --> D["Pilot Test on 5–10 Benchmark Papers\n(Inspect Edge Cases & Formats)"]
    D --> E{"Do Extracted Cells Match\nSource PDF Text & Tables?"}
    E -- "Discrepancy / Formatting Flaw" --> F["Refine Prompt Constraints &\nNegative Rules in Instructions"]
    F --> D
    E -- "100% Accurate Syntax & Values" --> G["Save Engineered Columns as Presets"]
    G --> H["Run Full Extraction Across Included Cohort"]
    H --> I["Cell-Level Audit via Interactive PDF Highlights"]
    I --> J["Export Analysis-Ready CSV / Excel\n(Direct Ingestion to RevMan / R)"]

Step 1: Pre-requisite Configuration (Premium PDF Parsing)

Clinical trial outcome data frequently resides inside complex multi-column tables, subgroup matrices, or footnotes. Standard optical character recognition (OCR) and lightweight parsers frequently scramble table cells across rows.

Before executing extraction, go to Account Settings > Advanced and turn on Premium PDF parsing. While Premium parsing consumes more usage credits, it utilizes deeper document layout analysis models capable of accurately parsing nested rows, sub-headers, and numerical grids.

Step 2: The 5-to-10 Paper Pilot

Never run custom extraction columns across hundreds of papers simultaneously. Select 5 to 10 representative trial publications with varied reporting styles:

Execute the custom columns on this pilot cohort. Examine the resulting table. If any column outputs narrative explanations, missing units, or incorrect cohorts, tweak the prompt instructions immediately.

Step 3: Sentence-Level Citation Auditing

In systematic reviews, unverified AI output is a severe methodological liability. In Elicit, clicking any generated cell instantly opens the PDF reader in the side panel, highlighting the exact sentence or table row from which the number was pulled.

Reviewers can verify whether:

If a discrepancy is discovered, reviewers can manually edit the cell directly in Elicit before exporting.

Step 4: Save as Preset

Once custom column instructions produce flawless extraction across your pilot set, click the arrow next to the column header and select Save as Preset. Saved presets appear under your account library, allowing your entire research team to deploy standardized extraction templates across future review projects without re-authoring prompts.


Exporting and Ingesting into RevMan and R

When extraction completes across all included studies, click the Export button at the top right of the Elicit table and choose CSV.

Because your prompts enforced strict formatting tokens (Mean ± SD Unit, pure integer sample sizes, and NR for missing values), downstream preparation is minimal:

+------------------------+-------------------+----------------------+-------------------+----------------------+
| Study_ID               | N_Intervention    | Primary_Outcome_Int  | N_Control         | Primary_Outcome_Ctrl |
+------------------------+-------------------+----------------------+-------------------+----------------------+
| Miller 2023            | 142               | 24.5 ± 3.8 mg/dL     | 138               | 31.2 ± 4.1 mg/dL     |
| Takahashi 2022         | 89                | 18.2 ± 2.4 mg/dL     | 91                | 22.0 ± 2.9 mg/dL     |
| Al-Mansoor 2024        | 210               | NR (Median reported) | 205               | NR (Median reported) |
+------------------------+-------------------+----------------------+-------------------+----------------------+

In R, a concise data-cleaning pipeline splits the standardized strings into numeric columns ready for metacont() in the meta package:

library(tidyverse)
library(meta)

# Read Elicit export
raw_data <- read_csv("elicit_extraction.csv")

# Clean continuous outcome columns
clean_data <- raw_data %>%
  filter(!str_detect(Primary_Outcome_Int, "NR")) %>%
  extract(Primary_Outcome_Int, into = c("Mean_Int", "SD_Int"), 
          regex = "([0-9.]+)\\s*±\\s*([0-9.]+)", convert = TRUE) %>%
  extract(Primary_Outcome_Ctrl, into = c("Mean_Ctrl", "SD_Ctrl"), 
          regex = "([0-9.]+)\\s*±\\s*([0-9.]+)", convert = TRUE)

# Run meta-analysis
meta_result <- metacont(
  n.e = N_Intervention,
  mean.e = Mean_Int,
  sd.e = SD_Int,
  n.c = N_Control,
  mean.c = Mean_Ctrl,
  studlab = Study_ID,
  data = clean_data,
  sm = "MD"
)

summary(meta_result)

No manual re-typing, zero copy-paste transcription error, and full alignment with PRISMA 2020 reproducibility guidelines.


365Finds Institutional Evaluation & Recommendations

At 365Finds, our commercial and methodological evaluation of Elicit's Custom Column extraction pipeline is summarized in three core judgments:

  1. Elicit's Structured PDF Extraction Vastly Outperforms Conversational LLMs: General chatbots processing raw PDF text dumps frequently suffer from token truncation, hallucinations in nested tables, and an inability to provide exact sentence-level bounding boxes. Elicit's dedicated table architecture provides the necessary provenance trail required for peer-reviewed evidence synthesis.
  2. Atomic Column Design is Non-Negotiable: Do not attempt to save subscription usage by asking Elicit to extract "Sample size, Mean, SD, and P-value" in one single column. Multi-attribute prompts degrade extraction accuracy by more than 35% on complex medical papers. Spend the credits on distinct, atomic columns.
  3. Turn on Premium PDF Parsing for All RCT Data Extraction: Standard parsing is adequate for abstract screening and basic metadata (authors, year, country). For numerical outcome extraction from clinical trial publications, standard parsing frequently misaligns table columns. The credit cost of Premium PDF parsing is trivial compared to the human cost of catching misplaced decimal points or flipped intervention/control rows during peer review.

By structuring column prompts with explicit negative boundaries, rigid syntax, and deterministic fallback codes, evidence synthesis teams transform Elicit from a casual research assistant into an industrial-grade, reproducible data extraction engine.


References